[title] Probe Alignment
[* icon_note] If you have the Flexplate upgrade make sure it is on the platform before starting.
-[* black] Click "motors off" in Pronterface.
-[* black] Lower the gantry by hand so that the nozzle comes close to the print surface. Once close enough the red light on the probe should come on.
- [* icon_caution] The nozzle tip should always remain above the surface when the probe is triggered. The bottom of the probe should always remain above the tip of the nozzle.
-[* icon_note] Nozzle too close or hits the print surface before the red light on the probe comes on:
+[* red] Click "motors off" in Pronterface.
+[* black] Lower the gantry by hand so that the nozzle comes close to the print surface. Once close enough the red light on the probe should come on ***before ***the nozzle hits the print surface.
+[* icon_note] Ideally, when the probe is triggered (as soon as its light shines) the tip of the nozzle should be no more than 1mm above the print surface.
+[* icon_caution] Nozzle hits the print surface before the red light on the probe comes on:
[* black] Lower the probes position on the mount and check again.
-[* icon_note] Red light on probe but nozzle tip is too far away from the print surface:
+[* icon_caution] Red light on probe but nozzle tip is too far away from the print surface:
[* black] Raise the probes position on the mount and check again.

Image 1

No previous image

Added