Skip to main content
/

Site Navigation

Your Account

Choose Language

Changes to Step #19

Edit by Makertech

Edit approved by Makertech

Before
After
Unchanged

Step Lines

+[title] Probe Alignment
+[* icon_note] If you have the Flexplate upgrade make sure it is on the platform before starting.
+[* black] Click "motors off" in Pronterface.
+[* black] Lower the gantry by hand so that the nozzle comes close to the print surface. Once close enough the red light on the probe should come on.
+ [* icon_caution] The nozzle tip should always remain above the surface when the probe is triggered. The bottom of the probe should always remain above the tip of the nozzle.
+[* icon_note] Nozzle too close or hits the print surface before the red light on the probe comes on:
+ [* black] Lower the probes position on the mount and check again.
+[* icon_note] Red light on probe but nozzle tip is too far away from the print surface:
+ [* black] Raise the probes position on the mount and check again.