Check your probe assembly:
-
Check you're able to press the stainless steel ball to trigger the switch.
-
Check that the bolts holding the switch in place are secure.
-
-
-
Run the cable for the probe down to the base through the beds cable loom.
-
The 4-pin header side of the cable should go into the base.
-
Plug the 4-pin header into the Octopus Max board.
-
-
-
Cut the magnetic base to gain access to the mounting hole for the probe.
-
Fix the probe to the platform with the included M5x20mm bolt.
-
Plug the cable into the probe.
-
-
-
Power up the printer.
-
Use Termius to copy the tools_calibrate.py file into the ~/klipper/Klippy/Extras folder.
-
-
-
Add the calibrate-offsets.cfg file to your config files folder.
-
Also update your printers other config files also.
-